HOME FITS CABLE INTRANET KOREAN ENGLISH JAPANESE MONGOLIA
> Products > SPECIAL CABLE > CO2 Welding ALL IN ONE Cable


  CO2 Welding ALL IN ONE Cable
Application While existing CO2 single cables, which have been generally used to weld iron plates at the majority of dockyards, are composed of 8 strands of control cables (0.75㎟ A, 0.85㎟ TA scan line) and 2 strands of power cords (1.25㎟ A, 1.25㎟ TA scan line), our "ALL IN ONE CABLE" has no welding machine control cable. Namely, it uses two strands of power cords (1.25㎟ A, 1.25㎟ TA) of the wire feeder motor to comprise an electric wire-based communication network and digitally control the main body of a welding machine.
Construction Power Supply Conductor : 5th-Grade Twisted Copper Wire(A or TA / Multi-Sized Strand) or Hi-Wrap Wire
Power Supply Insulation : XLPE Scan Line or Corresponding Electric Wire
Gas Hose : XL-TPE or Corresponding TPE
Conductor for Welding Power
Sheath : FR-TPE
Color Power Supply : Black, White
Outer Cover : Yellow, Blue, Orange, Red or Other Colors Requested
Temperature Rating 120 ℃
Certificate Head of Korea Intellectual Property Office (10-0830184, May 9, 2008)
Marking ALL IN ONE (10-0830184) CABLE 62㎟ + 2C CELNICS - KISEONG 0000


Power Copper Control wire
Nominal cross
-sectional
area
Composition Max.
Conductor Resistance
at 20℃
Nominal cross
-sectional area
Composition Approx. Diameter Thickness of insulation
Specified value
Max.
Conductor Resistance
at 20℃
mm2 No./mm Ω/㎞ mm2 No./mm mm mm Ω/㎞
62 18/67/0.26mm 0.31 1.25 50/0.18 1.3 0.6 14.7

Hose Overall Voltage
in
Water
Packing
Length
Approx.
Weight
Approx.
Inside
Diameter
Thickness of
Hose Specified
value
Approx.
Diameter
Sheathed
Thickness
Mean overall
diameter
mm mm mm mm mm kV/min m kg/㎞
8.5 3 14.5 2 22 1 500 795

☞ Note : Due to the use and structural characteristics, thess technical specifications and physical characteristics can change without prior notice through a series of researches and developments by the patent holder and manufacturer. As such, you are recommended to visit the company and check any change in technical specifications.